Sensible heating of a stream

Heat needed to warm a flowing fluid by a given temperature rise.

Ref
CHE-03
Rev
v1
Field
Chemical
Result
Q̇ [kW]

Q̇ heat rate in kW, ṁ mass flow in kg/s, cp specific heat in kJ/(kg·K), Tout and Tin outlet and inlet temperatures. Steady, single-phase, constant pressure, no shaft work.

The heat needed to warm a flowing fluid equals the mass flowing each second, times how much heat each kilogram needs per degree, times the temperature rise.

Calculator

Solve for
kW
kg/s
0.0550
kJ/(kg·K)
0.55
°C
040
°C
50100
  • Temperature rise40 K
  • Energy per hour1,204 MJ

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Heat duty (kW) current value 334.4 kW
ṁMass flowKey driver
8.368,360
ToutOutlet temperature
251669
cpSpecific heat
40400
TinInlet temperature
167502
  • Water’s high specific heat makes it an efficient coolant: it carries four times the heat of air per kilogram per degree.
  • The formula covers temperature change only. A change of phase (boiling, condensing) needs latent heat as well.
  • The same equation gives the cooling duty with the sign reversed.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (kW)Local stepChange in result
ṁ Mass flow0.05 to 50 kg/s8.368,3608,352+10%+10 %
Tout Outlet temperature50 to 100 °C250.8668.8418+10%+15 %
cp Specific heat0.5 to 5 kJ/(kg·K)40400360+10%+10 %
Tin Inlet temperature0 to 40 °C167.2501.6334.4+10%−5 %

Sweep of Outlet temperature

Outlet temperature (°C)Heat duty (kW)
50250.8
56.25303
62.5355.3
68.75407.5
75459.8
81.25512
87.5564.3
93.75616.5
100668.8

Sweep one variable

Heat duty (kW)Hover, touch, or use the arrow keys on the chart
300400500600700 5060708090100 Outlet temperature (°C) now 334.4

Variables and how each one contributes

Q̇

Heat duty

Result · kW

What the equation gives you. Everything else feeds it.

ṁ

Mass flow

kg/s · typical 0.05 to 50

Mass of fluid per second. Directly proportional.

cp

Specific heat

kJ/(kg·K) · typical 0.5 to 5

Water 4.18, air 1.0, oil about 2. Directly proportional.

Tin

Inlet temperature

°C · typical 0 to 40

Temperature entering. Lowers the duty as it rises (smaller rise).

Tout

Outlet temperature

°C · typical 50 to 100

Temperature leaving. Raises the duty as it rises.

Worked example with the values above

  1. Temperature rise: 60 − 20 = 40 K.
  2. Q = ṁcpΔT = 2 × 4.18 × 40.
  3. Q = 334.4 kW.

Assumptions and limits

  • Steady flow, single phase, constant cp.
  • Kinetic and potential energy changes neglected.
  • No shaft work.

Common mistakes

  • Forgetting latent heat if a phase change occurs.
  • Mixing kJ with J.
  • Using volume flow without converting to mass flow.

Statistics and uncertainty

Temperature rise is the weakest term when the difference is small: ±0.5 K on both thermometers gives ±0.7 K on a 40 K rise (1.8%). The specific heat varies by a few per cent with temperature and composition.

Where it is used

  • Heater and cooler sizing.
  • Engine and electronics coolant loops.
  • Heat exchanger duty checks.

Maths you need

  • Specific heat: energy per kg per degree
  • Mass flow: kg per second

Related formulas