Your Equation

Library / Heat Transfer / HTR-13

Heat Transfer

Fin parameter of a straight fin

Combined measure of how quickly heat leaves a straight fin by convection compared with how easily it is conducted along it.

Ref
HTR-13
Rev
v1
Field
Heat Transfer
Result
mf [1/m]

The fin parameter m = √(hP/(kAc)) sets how quickly the temperature drops along a fin: the excess temperature falls off roughly as e−mx. A large m (strong convection, thin fin, poor conductor) means the fin is cold after a short distance, so a long fin is wasted. 1/m is the characteristic length. For a round pin, m = √(4h/(kd)).

Combined measure of how quickly heat leaves a straight fin by convection compared with how easily it is conducted along it. A large value means the temperature falls off quickly along the fin.

Calculator

Solve for
1/m
W/(m² K)
5500
mm
5500
W/(m K)
1400
mm²
55,000
  • Characteristic length, 1/m141.4 mm
  • mL for a 100 mm fin0.7071
  • Length beyond which the fin behaves as infinitely long (about 2/m)282.8 mm

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Fin parameter (1/m) current value 7.071 1/m
kThermal conductivity of the finKey driver
5100
hConvection coefficient
3.1631.6
AcCross-sectional area of the fin
0.88628
PExposed perimeter of the fin
2.8228.2
  • For a round pin 9.99 mm in diameter (perimeter 31.4 mm), m = 7.07 m⁻¹, so the temperature excess falls to 37 % in 141 mm. A pin about 283 mm long (2/m) already behaves as if it were infinitely long.
  • Using a better conductor (higher k) or a thicker fin lowers m and lets the fin stay warm for longer; stronger cooling (higher h) raises m and shortens the useful length.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (1/m)Local stepChange in result
k Thermal conductivity of the fin1 to 400 W/(m K)510095+10%−4.65 %
h Convection coefficient5 to 500 W/(m² K)3.16231.6228.46+10%+4.88 %
Ac Cross-sectional area of the fin5 to 5,000 mm²0.88628.0227.13+10%−4.65 %
P Exposed perimeter of the fin5 to 500 mm2.82228.2225.39+10%+4.88 %

Sweep of Convection coefficient

Convection coefficient (W/(m² K))Fin parameter (1/m)
53.162
66.8811.57
128.816.05
190.619.53
252.522.47
314.425.07
376.327.43
438.129.6
50031.62

Sweep one variable

Fin parameter (1/m)Hover, touch, or use the arrow keys on the chart
51015202530 100200300400500 Convection coefficient (W/(m² K)) now 7.071

Variables and how each one contributes

mf

Fin parameter

Result · 1/m

What the equation gives you. Everything else feeds it.

h

Convection coefficient

W/(m² K) · typical 5 to 500

The convection coefficient between the fin and the surrounding fluid, in W/(m² K) (about 10 to 25 for natural convection in air, higher for forced). Raises m with the square root of h: more convection removes heat faster so the temperature drops more quickly. Raising it by 5 (to 30) moves the result by +9.54 %, from 7.071 to 7.746 1/m.

P

Exposed perimeter of the fin

mm · typical 5 to 500

The exposed perimeter of the fin cross-section, in mm (for a round pin, πd). Raises m with the square root of the perimeter: more surface per unit length loses more heat. Raising it by 5 mm (to 36.4 mm) moves the result by +7.67 %, from 7.071 to 7.613 1/m.

k

Thermal conductivity of the fin

W/(m K) · typical 1 to 400

The thermal conductivity of the fin material, in W/(m K) (about 200 for aluminium, 400 for copper, 50 for steel). Lowers m with the inverse square root of the conductivity: a better conductor carries heat further. Raising it by 20 (to 220) moves the result by −4.65 %, from 7.071 to 6.742 1/m.

Ac

Cross-sectional area of the fin

mm² · typical 5 to 5,000

The cross-sectional area of the fin, in mm² (for a round pin, πd²/4). Lowers m with the inverse square root of the area: a thicker fin carries more heat along its length. Raising it by 10 mm² (to 88.5 mm²) moves the result by −5.82 %, from 7.071 to 6.66 1/m.

Worked example with the values above

  1. Convert units: P = 0.0314 m and Ac = 7.85×10−5 m². Numerator hP = 25 × 0.0314 = 0.785 W/(m K).
  2. Denominator k Ac = 200 × 7.85×10−5 = 0.0157 W m/K; ratio = 50 m⁻².
  3. m = √50 = 7.071 m⁻¹.

Assumptions and limits

  • A straight fin of uniform cross-section with one-dimensional conduction along its length.
  • A constant convection coefficient and a constant fin conductivity, with an insulated (adiabatic) tip.

Common mistakes

  • Mixing mm and m for P and Ac.
  • Using the perimeter of the base block rather than the fin cross-section.

Statistics and uncertainty

The convection coefficient h is the least certain input, often only known to ±25 %. Because m depends on √h, that becomes about ±12 % in m, and the useful fin length changes by the same fraction.

Where it is used

  • Judging how long a fin on a heat sink, cylinder barrel or electronics housing is useful.
  • Input to the heat transfer and efficiency of a fin.

Maths you need

  • Convection coefficient: heat per area per temperature difference
  • Conduction: heat flow through a solid by temperature gradient

Related formulas

Practise this formula