Your Equation

Library / Foundations: Chemistry / FCH-34

Foundations: Chemistry

Rate constant at a second temperature (Arrhenius)

Rate constant at one temperature from its value at another, for the same mechanism, assuming the activation energy and the pre-exponential factor stay constant over the range.

Ref
FCH-34
Rev
v1
Field
Foundations: Chemistry
Result
k2

The Arrhenius equation k = A exp(−Ea/RT) links the rate constant to temperature. Taking the ratio at two temperatures cancels the pre-exponential factor A: k₂ = k₁ exp[(Ea/R)(1/T₁ − 1/T₂)], with R = 8.314 J/(mol K). Temperatures are absolute (kelvin) and Ea is in kJ/mol. A higher temperature raises the rate constant, more steeply when Ea is large.

Rate constant at one temperature from its value at another, for the same mechanism, assuming the activation energy and the pre-exponential factor stay constant over the range.

Calculator

Solve for
1e-6100
kJ/mol
5300
K
2001,000
K
2001,000
  • Rate ratio, k₂/k₁1.926
  • Temperature rise, T₂ − T₁10 K
  • Activation energy that would just double the rate over this interval52.9 kJ/mol

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

Rate constant at T₂ () current value 0.01926
T2Second temperatureKey driver
5.08e-714,200
T1First temperature
1.36e-8379
k1Rate constant at the first temperature
1.93e-6193
EaActivation energy
0.01070.51
  • Warming from 298 K to 308 K multiplies the rate constant by 1.926 for Ea = 50 kJ/mol, so k rises from 0.01 to 0.01926.
  • A rule of thumb says a 10 K rise doubles the rate; here a 10 K rise gives a factor of 1.93, which works for activation energies near 50 kJ/mol at room temperature but is not general: it depends on Ea and on T.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing ()Local stepChange in result
T2 Second temperature200 to 1,000 K5.077e-714,20014,200+10%+490 %
T1 First temperature200 to 1,000 K1.356e-8379.2379.2+10%−84 %
k1 Rate constant at the first temperature1e-6 to 100 1.926e-6192.6192.6+10%+10 %
Ea Activation energy5 to 300 kJ/mol0.010680.50970.499+10%+6.77 %

Sweep of Second temperature

Second temperature (K)Rate constant at T₂
2005.077e-7
3000.01144
4001.717
50034.73
600257.8
7001,079
8003,158
9007,281
1,00014,200

Sweep one variable

Rate constant at T₂ ()Hover, touch, or use the arrow keys on the chart
0500010k15k 2004006008001000 Second temperature (K) now 0.01926

Variables and how each one contributes

k2

Rate constant at T₂

Result ·

What the equation gives you. Everything else feeds it.

k1

Rate constant at the first temperature

· typical 1e-6 to 100

The rate constant at the first temperature, in any unit; the result has the same unit. Raises k₂ in direct proportion, because k₂ is a multiple of k₁. Raising it by 0.005 (to 0.015) moves the result by +50 %, from 0.01926 to 0.02888.

Ea

Activation energy

kJ/mol · typical 5 to 300

The activation energy, in kJ/mol. Raises k₂ steeply when T₂ is above T₁, because the factor grows exponentially with Ea. Raising it by 5 kJ/mol (to 55 kJ/mol) moves the result by +6.77 %, from 0.01926 to 0.02056.

T1

First temperature

K · typical 200 to 1,000

The first temperature, in kelvin, at which k₁ was measured. Lowers k₂: with k₁ fixed, a warmer starting point leaves a smaller gap to T₂. Raising it by 2 K (to 300 K) moves the result by −12.6 %, from 0.01926 to 0.01683.

T2

Second temperature

K · typical 200 to 1,000

The second temperature, in kelvin, at which k₂ is wanted. Raises k₂: a higher temperature makes the reaction faster. Raising it by 2 K (to 310 K) moves the result by +13.4 %, from 0.01926 to 0.02184.

Worked example with the values above

  1. Exponent: (Ea/R)(1/T₁ − 1/T₂) = (50,000 / 8.3145) × (1/298 − 1/308) = 0.6552.
  2. Factor: e0.6552 = 1.926.
  3. k₂ = 0.01 × 1.926 = 0.01926.

Assumptions and limits

  • The rate constant follows the Arrhenius law with Ea constant over the temperature range.
  • Absolute temperatures in kelvin and the same reaction mechanism at both.

Common mistakes

  • Using degrees Celsius in place of kelvin.
  • Entering Ea in J/mol when kJ/mol is expected, or vice versa.
  • Extrapolating far beyond the temperature range where Ea was measured.

Statistics and uncertainty

The temperature appears in an exponent, so an error of 1 K at 300 K in a temperature difference changes the factor by about Ea/(RT²) per kelvin, about 7 % per K for 50 kJ/mol near 300 K. Activation energies from only two temperatures carry large uncertainty; a straight-line fit of ln k against 1/T over several temperatures is much better.

Where it is used

  • Predicting how fast a reaction, ageing process or degradation proceeds at a different temperature.
  • Estimating the shelf life of propellants and energetic materials at storage temperature.

Maths you need

  • Activation energy: the energy barrier that must be overcome
  • Absolute temperature: in kelvin, starting at absolute zero

Related formulas

Practise this formula