Your Equation

Library / Fluid Mechanics / FLU-12

Fluid Mechanics

Pump flow rate after a speed change

Flow of a given pump when its speed changes, at corresponding operating points with the same impeller diameter.

Ref
FLU-12
Rev
v1
Field
Fluid Mechanics
Result
Q2 [L/s]

For a centrifugal pump the flow rate is proportional to the speed: Q₂/Q₁ = N₂/N₁ (the first of the affinity laws). Doubling the speed doubles the flow, but the head rises four times and the power eight times, which is why speed control is so effective at saving energy. The speed unit does not matter as long as both are the same.

Flow of a given pump when its speed changes, at corresponding operating points with the same impeller diameter. Flow is directly proportional to speed.

Calculator

Solve for
L/s
L/s
11,000
rpm
5004,000
rpm
5004,000
  • Speed ratio, N₂/N₁1.207
  • Change in flow10.34 L/s
  • New flow in m³/h217.2 m³/h

What drives the result

Each variable is moved across its typical range while the others stay at the values above. The longest bar is the key driver.

New flow rate (L/s) current value 60.34 L/s
Q1Original flow rateKey driver
1.211,210
N1Original speed
21.9175
N2New speed
17.2138
  • Raising the speed from 1,450 to 1,750 rpm (20.7 % faster) raises the flow from 50 to 60.34 L/s.
  • At the same time the head would rise by 45.7 % and the power by 75.8 %, so a modest increase in flow costs much more energy.
Chart data as tables

Ranked variables

VariableTypical rangeLowest resultHighest resultSwing (L/s)Local stepChange in result
Q1 Original flow rate1 to 1,000 L/s1.2071,2071,206+10%+10 %
N1 Original speed500 to 4,000 rpm21.88175153.1+10%−9.09 %
N2 New speed500 to 4,000 rpm17.24137.9120.7+10%+10 %

Sweep of New speed

New speed (rpm)New flow rate (L/s)
50017.24
937.532.33
1,37547.41
1,81362.5
2,25077.59
2,68892.67
3,125107.8
3,563122.8
4,000137.9

Sweep one variable

New flow rate (L/s)Hover, touch, or use the arrow keys on the chart
20406080100120140 500150025003500 New speed (rpm) now 60.34

Variables and how each one contributes

Q2

New flow rate

Result · L/s

What the equation gives you. Everything else feeds it.

Q1

Original flow rate

L/s · typical 1 to 1,000

The original flow rate, in litres per second. Raises the new flow in direct proportion. Raising it by 5 L/s (to 55 L/s) moves the result by +10 %, from 60.34 to 66.38 L/s.

N1

Original speed

rpm · typical 500 to 4,000

The original speed, in rpm. Lowers the new flow, because the speed ratio N₂/N₁ becomes smaller. Raising it by 50 rpm (to 1,500 rpm) moves the result by −3.33 %, from 60.34 to 58.33 L/s.

N2

New speed

rpm · typical 500 to 4,000

The new speed, in rpm. Raises the new flow in direct proportion. Raising it by 50 rpm (to 1,800 rpm) moves the result by +2.86 %, from 60.34 to 62.07 L/s.

Worked example with the values above

  1. Speed ratio: N₂/N₁ = 1,750 / 1,450 = 1.207.
  2. Multiply the original flow: 50 × 1.207.
  3. Q₂ = 60.34 L/s.

Assumptions and limits

  • The same pump and fluid at two speeds, with the operating point moving to a dynamically similar point on the pump curve.
  • The impeller diameter is unchanged and the efficiency is the same at both points (a good approximation for modest speed changes).

Common mistakes

  • Applying the laws to a system with a large static head: the new operating point is where the new pump curve meets the system curve, not on the affinity parabola.
  • Using them for large speed changes, where the efficiency changes.

Statistics and uncertainty

The flow is in direct proportion to speed, so a 1 % error in the speed gives a 1 % error in the flow. In practice, slip in the drive can make the actual speed a little different from the nameplate value; use a measured speed.

Where it is used

  • Setting a variable-speed pump to a required flow.
  • Estimating the flow when a pump is changed to a different motor speed or pulley.

Maths you need

  • Pump curve: head against flow at a fixed speed
  • Similarity: flows scale with speed, heads with speed squared

Related formulas

Practise this formula